Length Measurement of RF Cable Assembly

  • A:  For two ends with straight connectors, the assembly length is measured from one connector end to the other connector end,
  • B:  For two ends with right angle connectors, use the pin center-line as shown in below drawing.
  • C:  For two ends with one straight connector and another right angle connector, the assembly length is measured from straight connector ‘s end to the right angle connector’s pin center-line.
  • D:  For two ends with one straight connector and another straight cut lead, the assembly length is measured from straight connector ‘s end to the straight cut lead end.

 

 

RF Cable Assembly Tolerance

Length (mm) Tolerance (+/- )
0-100 3
101-500 4
501-1000 5
1001+ Length*1.5%